Sprayer Water Calibration
Calculate field water application rate and work capacity from measured water flow, travel speed and effective width
Use a discharge test performed with water only. Repeat the measurement after changing spray pressure, active nozzles or travel conditions.
Calculates water volume and theoretical work capacity during straight-line travel. It does not assess spray uniformity, drift or chemical dosage.
Results
—L/ha
- Water application per 10a
- —L/10a
- Total flow from active nozzles
- —L/min
- Measured flow per boom nozzle
- —L/min
- Measured travel speed
- —km/h
- Theoretical area capacity
- —ha/h
- Total flow required for target rate
- —L/min
- Target flow per boom nozzle
- —L/min
- Speed for target rate at current flow
- —km/h
- Difference from target (measured − target)
- —%
- Theoretical area covered per tank
- —ha
- Continuous spraying time per tank
- —min
Results update automatically when the required values are entered.
Method, applicability and sources
Calculation method
Total flow Q (L/min) = collected water (mL) ÷ collection time (s) × 0.06. For a boom sprayer, multiply this by the number of nozzles. Measured speed v (km/h) = 3.6 × travel distance (m) ÷ travel time (s). Effective travel width W (m) is effective width per nozzle × nozzle count for a boom sprayer, row spacing for two-sided air-blast spraying with 1 pass, and row spacing ÷ 2 for one-sided spraying with 2 passes. Water application rate R (L/ha) = 600 × Q ÷ (v × W); theoretical area capacity = v × W ÷ 10 (ha/h). For a positive target Rₜ, required flow Qₜ = Rₜ × v × W ÷ 600, and required speed at current flow vₜ = 600 × Q ÷ (Rₜ × W). Area covered per tank = usable water ÷ R; continuous spraying time = usable water ÷ Q.
Worked example (hypothetical values)
For a boom sprayer collecting 600 mL from 1 nozzle in 30 seconds, with 5 nozzles each covering 0.5 m and travelling 100 m in 60 seconds: Q = 6 L/min, v = 6 km/h, W = 2.5 m, R = 240 L/ha (24 L/10a), and area capacity = 1.5 ha/h. A target of 200 L/ha requires a total flow of 5 L/min or, with the current flow unchanged, a speed of 7.2 km/h.
Applicability and limitations
Calibration of boom sprayers or air-blast sprayers travelling between rows, applying water at constant pressure, engine speed and travel speed. Does not calculate pesticide or fertilizer concentration, dilution or product-specific dosage; spray uniformity, droplet size, drift or pressure corrections; or turns, overlapping passes and stopped time. One-sided spraying applies only to two passes per row, one along each side, under identical conditions.
Method and sources
Method: water-spray-calibration-metric-v1.0 (flow and area balance accounting for effective spray width and number of passes). Data recorded: 2026-11-14.