Search Tools

Calculate field water application rate and work capacity from measured water flow, travel speed and effective width

Use a discharge test performed with water only. Repeat the measurement after changing spray pressure, active nozzles or travel conditions.

Calculates water volume and theoretical work capacity during straight-line travel. It does not assess spray uniformity, drift or chemical dosage.

What to calculate

For a boom sprayer, collect from 1 nozzle; for two-sided air-blast spraying, collect the total from both sides; for one-sided spraying, collect the total from one side. Use the same pressure and engine speed as in actual operation.

Number of nozzles with the same flow rate. Check each nozzle if their outputs differ.

For broadcast spraying, enter nozzle spacing. For band spraying, enter the band width covered by 1 nozzle. Do not use the apparent width of the spray plume.

Measure under the same travel conditions as in the field. If outward and return times differ, repeat the measurement and use the mean time.

Enter only if a target water application rate is known. Chemical dosage is not calculated here.

Water actually available for spraying, rather than the full tank capacity. The theoretical calculation excludes turns, residual water and losses.

Results

Results update automatically when the required values are entered.

Method, applicability and sources

Calculation method

Total flow Q (L/min) = collected water (mL) ÷ collection time (s) × 0.06. For a boom sprayer, multiply this by the number of nozzles. Measured speed v (km/h) = 3.6 × travel distance (m) ÷ travel time (s). Effective travel width W (m) is effective width per nozzle × nozzle count for a boom sprayer, row spacing for two-sided air-blast spraying with 1 pass, and row spacing ÷ 2 for one-sided spraying with 2 passes. Water application rate R (L/ha) = 600 × Q ÷ (v × W); theoretical area capacity = v × W ÷ 10 (ha/h). For a positive target Rₜ, required flow Qₜ = Rₜ × v × W ÷ 600, and required speed at current flow vₜ = 600 × Q ÷ (Rₜ × W). Area covered per tank = usable water ÷ R; continuous spraying time = usable water ÷ Q.

Worked example (hypothetical values)

For a boom sprayer collecting 600 mL from 1 nozzle in 30 seconds, with 5 nozzles each covering 0.5 m and travelling 100 m in 60 seconds: Q = 6 L/min, v = 6 km/h, W = 2.5 m, R = 240 L/ha (24 L/10a), and area capacity = 1.5 ha/h. A target of 200 L/ha requires a total flow of 5 L/min or, with the current flow unchanged, a speed of 7.2 km/h.

Applicability and limitations

Calibration of boom sprayers or air-blast sprayers travelling between rows, applying water at constant pressure, engine speed and travel speed. Does not calculate pesticide or fertilizer concentration, dilution or product-specific dosage; spray uniformity, droplet size, drift or pressure corrections; or turns, overlapping passes and stopped time. One-sided spraying applies only to two passes per row, one along each side, under identical conditions.

Method and sources

Method: water-spray-calibration-metric-v1.0 (flow and area balance accounting for effective spray width and number of passes). Data recorded: 2026-11-14.