Aquarium Heater Load and Heating Time
Calculate steady-state aquarium heat losses and a reference time for the specified electric heater to raise the water from its current to its target temperature.
Enter heat transfer coefficients and evaporation rates confirmed for the tank's installation conditions.
Results
—W
—hours
- Total heat loss at target (negative means heat gain)
- —W
- Sidewall and bottom heat losses
- —W
- Water-surface sensible heat loss
- —W
- Latent heat loss from evaporation
- —W
- Required maintenance duty cycle
- —%
- Heat needed to warm the water alone
- —kWh
Results update automatically when the required values are entered.
Method, applicability and sources
Calculation method
Rectangular tank: sidewall area Aside=2(length+width)×water depth; bottom area Abottom=length×width; water surface area Asurface=Abottom (cm²→m²). Heat loss Q=Uside Aside(Twater−Troom)+Ubottom Abottom(Twater−Troom)+hsurface Asurface(Twater−Troom)+evaporation mass flow×latent heat. Maintenance power=max(0,Q)/efficiency. Water mass=actual water volume×0.997047013 kg/L; specific heat capacity 4181.44618 J/(kg·K); latent heat of evaporation approximately 2.443 MJ/kg (25°C). With C=m×specific heat capacity, K=ΣUA, Peffective=rated power×efficiency, and Qevap=evaporation heat loss in W, heating follows C dT/dt=Peffective−K(T−Troom)−Qevap. For K>0, t=(C/K) ln[(Peffective−Qevap−K(Tstart−Troom))/(Peffective−Qevap−K(Ttarget−Troom))]. For K=0, t=C(Ttarget−Tstart)/(Peffective−Qevap). If net heating at the target is 0 or less, the target is not reached in finite time. Values are rounded only for display.
Worked example (hypothetical values)
Hypothetical example: rectangular tank 60×30 cm, water depth 30 cm, actual water volume 50 L, room temperature 20°C, water 22→26°C, sidewall U=4, bottom U=2, surface h=8 W/(m²·K), evaporation 10 g/h, heater 100 W, efficiency 95%. Sidewall area 0.54 m², bottom and surface areas 0.18 m², K=3.96 W/K, evaporation loss 6.78 W. Heat loss at target is 30.54 W and required power is 32.15 W. Heating takes 3.21 hours with heat losses and evaporation included using constant coefficients.
Applicability and limitations
Indoor freshwater tanks with specified constant room temperature, areas, heat transfer coefficients, and evaporation. Internal-dimensions mode applies to rectangular tanks; area mode uses separately determined wetted sidewall, bottom, and water-surface areas. Excludes saltwater; heat storage in fish, substrate, or glass; sunlight; heat from lighting and pumps; water changes; varying airflow; lid condensation and evaporation suppression; thermostat cycling; and safe equipment ratings. Does not automatically estimate heat transfer or evaporation, determine suitable temperatures for livestock, or assess equipment safety.
Methods used
- Tank heat balance with constant coefficients (First-order lumped heat-capacity model (2026-11-14)): scope Freshwater at 10–40°C with constant room temperature, specified tank geometry, and confirmed heat transfer/evaporation conditions; region Global
Method and sources
Method: First-order lumped heat-capacity model with constant UA and evaporation (2026-11-14). Water properties: Pátek et al. 2009 Table 8 / NIST WebBook SRD69 (298.15 K). Data recorded: 2026-11-14.