Search Tools

Evaluate input-referred noise contributions in an RF receiver while preserving the stage order

Enter verified power gains (not voltage gains) and stage noise figures defined using the same reference.

The usual reference temperature for NF is 290 K. Use the same reference for all stage noise figures. The entered temperature is used to calculate equivalent noise temperature.

Stages from signal input to output (in order)Required
RowPower gain (dB)Noise figure NF (dB)Actions
1

Paste 2 tab-separated columns into the leftmost field. Up to 32 rows.

Power gain is positive for amplification and negative for loss. NF must be at least 0 dB. Enter every stage and remove unused blank rows. Changing the stage order changes the result.

Results

Results update automatically when the required values are entered.

Method, applicability and sources

Calculation method

For stage i, power gain Gi=10^(gain dB/10) and noise factor Fi=10^(NF dB/10). The overall factor is F=1+Σ(i=1..n)[(Fi−1)/(G1×…×G(i−1))], with a denominator of 1 for the first stage. Overall NF=10log10(F) dB. The equivalent input noise temperature at reference temperature T0 is Te=(F−1)T0 K. Each stage’s contribution ΔFi is its additive term; contribution percentage=ΔFi/(F−1)×100%. Total gain (dB) is the sum of the stage gains (dB).

Worked example (hypothetical values)

TI’s 3-stage example: LNA1 (gain 12 dB, NF 1 dB), LNA2 (15 dB, 3 dB), and ADC (0 dB, 20 dB) at a reference temperature of 290 K give an overall NF of approximately 1.82 dB. Increasing the ADC NF to 25 dB gives approximately 2.90 dB.

Applicability and limitations

Linear RF receiver systems with power gains and noise figures specified at the same reference temperature and under the same measurement conditions. Does not correct for impedance mismatch, correlated noise, frequency response, differing bandwidths, mixer SSB/DSB differences, saturation or intermodulation. Automatic conversion of voltage gain and path loss, estimation of device specifications, and optimization by reordering stages are also excluded.

Method and sources

Method: E534 Friis power-gain cascade v1.0 (2026-11-14). Data recorded: 2026-11-14.