Search Tools

Package Gas Flushing and Residual Oxygen

Report an issue

Treat package headspace as one perfectly mixed chamber to estimate the relationship between flushing, theoretical residual oxygen, and gas use.

Theoretical values for perfect mixing at constant volume. They do not guarantee actual residual oxygen.

What to calculate

The gas space after subtracting the volume occupied by the product and other contents, not the total package volume.

No assumed air concentration is filled in automatically.

Enter the actual composition of the supplied nitrogen or gas mixture.

Volumetric flow rate converted to the same pressure and temperature as the package headspace.

Results

Results update automatically when the required values are entered.

Method, applicability and sources

Calculation method

Continuous flushing: C=Cg+(C0−Cg)exp(−Qt/V), gas use=Qt. Inverse: Qt/V=−ln((Ct−Cg)/(C0−Cg)). Vacuum flushing: C_n=Cg+(C0−Cg)(PL/PH)^n, supply-gas volume=nV(1−PL/PH), expressed at PH. Round the real-valued logarithmic solution up to obtain the required number of cycles. All pressures are absolute.

Worked example (hypothetical values)

Illustrative package headspace of 100 mL, initial oxygen 20%, and supply-gas oxygen 0%: continuous flushing at 100 mL/min for 1 minute gives theoretical residual oxygen of approximately 7.357589%. For 2 vacuum cycles with minimum pressure 25 kPa(abs) and maximum pressure 100 kPa(abs), theoretical residual oxygen is 1.25% and supply-gas volume is 150 mL, measured at 100 kPa.

Applicability and limitations

Theoretical packaging estimates with a known gas headspace excluding the product, uniform mixing, and ideal-gas behavior. Excludes entrained air in the product, dissolved gases, packaging permeability, leaks, reactions and respiration, CO₂ absorption, incomplete mixing, flow losses, volume changes in flexible packages, post-sealing changes, and assessments of shelf life or microbiological safety.

Methods used

  • Continuous flow with perfect mixing (2004 AIChE calculation model): scope Constant volume, constant flow, simultaneous inlet and outlet, and perfect mixing; region Global
  • Vacuum evacuation and refill (1997 UK ETBPP / 2004 AIChE calculation model): scope Isothermal, constant-volume absolute-pressure cycles with perfect mixing; region Global

Method and sources

Method: E222 ideal headspace dilution v1.0 (2004 AIChE / 1997 UK ETBPP equations). Data recorded: 2026-11-13.