Ƙarfin RAID da ake amfani da shi da sharuɗɗan jure gazawa
Ƙiyasta ƙarfin tsarin ajiya da ake iya amfani da shi da sharuɗɗan jure gazawa bisa RAID da haɗin diski
Ana shigar da ƙarfin ajiya a TB na decimal. Ana tallafa girman diski biyu; madadi da ke shirye dabam yake da diskin rukunin ajiya.
Sakamako
—TB
- Ƙarfin da ake iya amfani da shi (raka'o'in binary)
- —TiB
- Mafi ƙarancin adadin gazawar da tsarin zai jure
- —diski
- Mafi girman adadin gazawa bisa wuraren da suka gaza
- —diski
- Diski na rukunin RAID
- —diski
- Jimillar ƙarfin da aka girka
- —TB
- Ƙarfin ajiyar kariya
- —TB
- Bambancin girman da ba a amfani da shi
- —TB
- Ƙarfin da aka ware ga madadi
- —TB
- Sharaɗin ƙarfin diskin madadi da ke shirye
- —
- Rabon ƙarfin da aka girka da ake iya amfani da shi
- —%
Sakamako yana sabuntawa kai tsaye idan an shigar da ƙimomin da ake buƙata.
Hanyar lissafi, iyakokin amfani da tushe
Hanyar lissafi
N=jimillar adadi−madadi, C=mafi ƙarancin ƙarfin diskin rukuni (TB). RAID 0: N×C; RAID 1 (diski 2): C; RAID 5: (N−1)×C; RAID 6: (N−2)×C; RAID 10: (N÷2)×C. Bambancin da ba a amfani da shi=adadin manyan diski×(babban ƙarfin−ƙaramin ƙarfin). Ba a ƙara madadi cikin ƙarfin da ake amfani da shi da gazawar da ake jurewa ba sai bayan kammala dawo da bayanai.
Misalin lissafi (ƙimomi na misali)
RAID 5 na diski huɗu, biyu 4 TB kowanne da biyu 8 TB kowanne: ƙarfin da ake amfani da shi (4−1)×4=12 TB. An girka 24 TB gaba ɗaya; ba a amfani da 8 TB saboda bambancin girma, 4 TB kuma na parity ne.
Inda ya dace da iyakokin amfani
Ƙiyasin farko na ƙarfin ajiya da ajiyar kariya kafin tsara ma'ajiyar bayanai. Samfurin yana da mafi yawa girman diski biyu. Bai haɗa RAID 50/60, SHR/ZFS na musamman da sauransu, rukunin kariya da yawa, madubin RAID 1 na diski uku ko fiye, takamaiman nau'in diski biyu da suka gaza a RAID 10, iyakokin na'ura, dacewar diskin madadi, lokacin dawo da bayanai ko ainihin ƙarfin fayil ba.
Hanyoyin da aka yi amfani da su
- RAID 0, 5, 6, 10 (IBM Disk array capacities (2020-09-09)): iyakar amfani A rukuni ɗaya, lissafi bisa mafi ƙarancin ƙarfin diskin da ke ciki; yanki Na ƙasa da ƙasa
- Sharuɗɗan gazawar RAID 1, 5, 6, 10 (Dell PERC 9 User Guide): iyakar amfani RAID 1 — diski 2; RAID 10 — adadin madubin diski mai rabuwa da biyu; yanki Na ƙasa da ƙasa
Hanya da tushe
Hanya: IBM Disk array capacities (2020-09-09); Dell PERC 9 RAID level summary; 2026-11-13 implementation. Ranar rubuta bayanai: 2026-11-13.