RAID Usable Capacity and Fault Tolerance
Estimate logical usable capacity and failure-tolerance conditions from the RAID level and drive configuration.
Enter capacities in decimal TB. Up to 2 member-drive sizes are supported; hot spares are treated separately from array members.
Results
—TB
- Usable capacity (binary units)
- —TiB
- Minimum tolerated drive failures for this configuration
- —drives
- Maximum tolerated failures depending on placement
- —drives
- RAID member drives
- —drives
- Total installed drive capacity
- —TB
- Capacity used for redundancy
- —TB
- Unused capacity from size mismatch
- —TB
- Capacity reserved for spares
- —TB
- Hot-spare capacity requirement
- —
- Usable capacity as a percentage of installed capacity
- —%
Results update automatically when the required values are entered.
Method, applicability and sources
Calculation method
N = total drives − spares; C = smallest member capacity (TB). RAID 0: N × C; RAID 1 (2 drives): C; RAID 5: (N − 1) × C; RAID 6: (N − 2) × C; RAID 10: (N ÷ 2) × C. Unused mixed-size capacity = larger-drive count × (larger capacity − smaller capacity). Spares do not add to usable capacity or failure tolerance before rebuilding.
Worked example (hypothetical values)
A 4-drive RAID 5 with two 4 TB drives and two 8 TB drives has usable capacity (4 − 1) × 4 = 12 TB. Of the 24 TB installed, 8 TB is unused because of size mismatch and 4 TB is the parity equivalent.
Applicability and limitations
Estimating storage capacity and redundancy before configuring a RAID array. Supports at most 2 member-drive sizes. Excludes RAID 50/60, proprietary schemes such as SHR/ZFS, multiple redundancy groups, RAID 1 mirrors with 3 or more drives, specific failed-pair positions in RAID 10, hardware limits, hot-spare compatibility and rebuild time, and actual filesystem capacity.
Methods used
- RAID 0, 5, 6, and 10 (IBM Disk array capacities (2020-09-09)): scope Estimate with all members in the RAID group limited to the smallest member capacity; region Global
- RAID 1, 5, 6, and 10 failure conditions (Dell PERC 9 User Guide): scope RAID 1 uses 2 drives; RAID 10 uses an even number of drives in mirror pairs; region Global
Method and sources
Method: IBM Disk array capacities (2020-09-09); Dell PERC 9 RAID level summary; 2026-11-13 implementation. Data recorded: 2026-11-13.