Nemo kayan aiki

Sauya ƙimomin zafi na thermocouple da Pt100

Ba da rahoton matsala

Sauya juriya ko ƙarfin lantarki zuwa zafi, ko akasin haka, bisa daidaitattun halayen firikwensin

Zaɓi hanyar sauyawa ga Pt100 ko thermocouple K. Zangon zafin da aka nuna shi ne na daidaitattun ayyukan kwatance.

Abin da za a lissafa

Juriyar sashen firikwensin kaɗai. Kada a haɗa da juriyar wayoyi ko wasu abubuwa.

Sakamako

Sakamako yana sabuntawa kai tsaye idan an shigar da ƙimomin da ake buƙata.

Hanyar lissafi, iyakokin amfani da tushe

Hanyar lissafi

Pt100: R(t)=100×[1+At+Bt²] a 0–850 °C; R(t)=100×[1+At+Bt²+C(t−100)t³] a −200–0 °C. A=0.0039083, B=−5.775×10⁻⁷, C=−4.183×10⁻¹². Ga K, E(t) shi ne jerin polinom na NIST bisa zafi, tare da ƙarin sashin eksiponenshiyal a ≥0 °C. Ƙarfin lantarki da aka auna=E(mahaɗin auna zafi)−E(mahaɗin kwatance). Ana yin lissafin akasin haka ta hanyar raba zangon gida biyu akai-akai cikin iyakar da ta dace.

Misalin lissafi (ƙimomi na misali)

Pt100 a 100 °C: 138.5055 Ω (jadawalin kwatance ya zagaye zuwa 138.51 Ω). Thermocouple K a 100 °C da mahaɗin kwatance a 0 °C: kimanin 4.096 mV.

Inda ya dace da iyakokin amfani

Na’urori da aunawar zafi masu amfani da halayen Pt100 da aka ayyana (100 Ω a 0 °C) da thermocouple nau’in K. Ba ya tallafa wa JPt100, Pt1000, sauran ma’aunin zafi ta juriya, thermocouple da ba nau’in K ba, bambancin na’urori ko iyakar kuskure, juriyar wayoyi, kuskuren ma’auni, gyaran hayaniyar sigina ko daidaita ma’auni. Ba a faɗaɗa lissafi zuwa wajen zangon zafin aikin kwatance.

Hanyoyin da aka yi amfani da su

  • Halayen juriya na Pt100 da aka ayyana (IEC 60751:2022 §4.2): iyakar amfani −200~850 ℃、R₀=100 Ω; yanki Duk duniya
  • Ƙarfin lantarkin zafi na kwatance na thermocouple K (NIST Monograph 175 (1993) §7.3): iyakar amfani −270–1372 °C, aikin kwatance bisa 0 °C da gyaran tasirin mahaɗin kwatance; yanki Duk duniya

Hanya da tushe

Hanya: IEC 60751:2022 §4.2/NIST Monograph 175 (1993) §7.3, ITS-90. Ranar rubuta bayanai: 2026-11-13.