DRAM Timing and Row Access Budget
Compare the minimum waits for PRE, ACT and READ commands in a single DDR4 bank
Applies to a normal READ in a single DDR4 bank (AL=0). Assumes no waits from other commands and that required commands can be issued as soon as their timing constraints permit.
Results
—ns
- Clock cycles to first data
- —clock cycles
- DRAM clock period (tCK)
- —ns
Results update automatically when the required values are entered.
Method, applicability and sources
Calculation method
For effective transfer rate R (MT/s), tCK (ns) = 2000 ÷ R. A row hit takes CL clock cycles; a precharged bank takes tRCD + CL clock cycles. If a different row is open and a clock cycles have elapsed since its ACT, the earliest PRE time is p=max(0,tRAS−a), the next ACT time is b=max(p+tRP,tRC−a), READ can be issued at b+tRCD, and first data arrives at b+tRCD+CL. Enter all configured timings as integer clock cycles; tRC ≥ tRAS + tRP is required. Convert to ns using clock cycles × tCK. Only displayed values are rounded, to 4 decimal places (6 for tCK).
Worked example (hypothetical values)
For DDR4-3200, CL22, tRCD22, tRP22, tRAS52 and tRC74, a row hit takes 22 clock cycles = 13.75 ns, and a precharged bank takes 44 clock cycles = 27.5 ns. With a different row open and 52 clock cycles elapsed since ACT, PRE is issued immediately, the next ACT after 22 clock cycles, and first data after 66 clock cycles (41.25 ns).
Applicability and limitations
Reference calculation for memory configurations with known configured DDR4 timings in clock cycles. Does not cover DDR5 or LPDDR, recovery from preceding commands such as tRTP/tWR, tCCD/tRRD/tFAW, refresh, bus contention, memory controllers, caches, CPU round-trip latency, measured performance, or stability assessment.
Method and sources
Method: E911 DDR4 single-bank READ timing v1.0 (2026-11-14). Data recorded: 2026-11-14.