Flash Steam and Condensate Recovery
Estimate the theoretical mass balance of flash steam and liquid condensate after pressure reduction
Enter verified water and steam properties. Enthalpy is not inferred from pressure alone.
Results are theoretical liquid-vapor separation quantities. Actual recovery depends on equipment operating conditions.
Results
—kg/h
- Flash fraction (by mass)
- —%
- Remaining condensate after pressure reduction
- —kg/h
Results update automatically when the required values are entered.
Method, applicability and sources
Calculation method
Flash fraction x = (h1 − hf2) / hfg2. h1 is inlet condensate specific enthalpy, hf2 is saturated-liquid enthalpy at outlet pressure, and hfg2 is latent heat at outlet pressure, all in kJ/kg. If h1 ≤ hf2, flash fraction is 0. If h1 > hf2 + hfg2, the outlet is on the superheated side and this saturated liquid-vapor separation formula does not apply. Flash-steam flow (kg/h) = inlet condensate flow × x; remaining condensate flow (kg/h) = inlet condensate flow × (1 − x). Assumes steady, adiabatic, isenthalpic pressure reduction.
Worked example (hypothetical values)
Spirax Sarco example 14.6.1: inlet 7 bar(g), outlet 0 bar(g), inlet condensate enthalpy 721 kJ/kg, outlet saturated-liquid enthalpy 419 kJ/kg, latent heat 2,257 kJ/kg, and inlet flow 250 kg/h. Flash fraction is about 13.4%, flash-steam flow about 33.5 kg/h, and remaining condensate about 216.5 kg/h.
Applicability and limitations
Approximately steady, adiabatic pressure reduction from liquid condensate to lower-pressure saturated liquid-vapor or subcooled liquid, at gauge pressures of 0 bar(g) or above. Does not calculate fluid properties, vacuum systems, nonadiabatic processes, pipe losses, steam leakage, two-phase pipe or vessel sizing, actual recovery efficiency, superheated-steam conditions or fuel economics.
Method and sources
Method: Enthalpy balance v1.0 (checked November 13, 2026). Data recorded: 2026-11-13.