Potting Substrate Air, Water, and Solid Fractions
Calculate the three volume fractions and retained-water fraction after a fixed drainage period from measured substrate mass and volume.
Calculation conditions: 30 minutes of immersion, 30 minutes of gravity drainage, drying at 60 °C for 3 days, and water density of 1.000 g/mL. Pot mass is excluded.
Results
—%
—%
—%
- Total porosity (water + air)
- —%
- Water drained from saturation
- —mL
- Drained-water volume fraction
- —%
- Residual air at saturation (estimated)
- —%
- Dry bulk density
- —g/mL
Results update automatically when the required values are entered.
Method, applicability and sources
Calculation method
V = filled substrate volume (mL), Md = dry mass (g), Msat = saturated mass before drainage (g), Mdr = mass after 30 minutes of drainage (g), ρs = particle density (g/mL), and ρw = 1.000 g/mL. Solid volume Vs = Md/ρs; pore volume Vv = V − Vs. Water volume Vw = (Mdr − Md)/ρw; air volume Va = V − Vs − Vw. Each phase fraction = phase volume/V × 100; porosity = (V − Vs)/V × 100. Drained water = (Msat − Mdr)/ρw. Residual air at saturation = Vv − (Msat − Md)/ρw; air after drainage = drained water + residual air. Water density is an experimental approximation without temperature correction.
Worked example (hypothetical values)
Hypothetical example: filled volume 100 mL, dry mass 25 g, particle density 2.5 g/mL, saturated mass 115 g, and mass after 30 minutes of drainage 85 g. Solids occupy 10 mL, water 60 mL, and air 30 mL, giving a solid fraction of 10%, water retention of 60%, air fraction of 30%, and porosity of 90%.
Applicability and limitations
Known internal pot or cylinder volume, with the same substrate weighed after drying, saturation, and 30 minutes of drainage, excluding container mass. Does not assess growth suitability, root oxygen supply, plant-available water, drainage-rate changes over time, pF curves, or fertilizer dose. Use caution when substrate is lost, swells, or dissolves, or when directly comparing different drying conditions.
Methods used
- Three-phase volume balance after a fixed 30-minute drainage period (Nguyen et al. 2022 §2.3; Gunma Prefecture published method (accessed 2026-11-14)): scope Samples with measured volume, dry, saturated, and drained masses for the same substrate, and known dry particle density; region Global
Method and sources
Method: Nguyen et al., Agronomy 2022, 12(2):420 §2.3 + Gunma Prefecture, “Measuring Soil Physical Properties,” three-phase equations; fixed 30-minute drainage, v1. Data recorded: 2026-11-14.
- Nguyen et al., Agronomy (2022) 12(2):420, §2.3 Substrate Hydrological Properties(DOI:10.3390/agronomy12020420)
- Gunma Prefecture, Gunma Agrinet: “Measuring Soil Physical Properties” — three-phase composition, bulk density, and macropore measurement
- University of Georgia Cooperative Extension, Circular 1292-04 (2024), container capacity / air space / total porosity