Search Tools

Constant-Head and Falling-Head Hydraulic Conductivity

Report an issue

Calculate hydraulic conductivity from water flow observed in a laboratory soil permeability test.

Assumes one-dimensional Darcy flow through a saturated cylindrical specimen. Does not include water-temperature correction or verification of test-procedure compliance.

What to calculate

Diameter of the cylindrical specimen perpendicular to flow, used to calculate cross-sectional area A.

Specimen length L along the flow direction.

Seconds in the same interval used to record head or outflow volume.

Head difference Δh maintained throughout the constant-head test.

Volume V of water discharged during the elapsed time under steady conditions.

Results

Results update automatically when the required values are entered.

Method, applicability and sources

Calculation method

A=π(D/2)² is specimen cross-sectional area; a=π(d/2)² is standpipe area. Constant-head: k=V L/(A Δh t). Falling-head: k=(a L/A t) ln(h₁/h₂). D, d, L, Δh, h₁, and h₂ are in cm; V is in cm³; t is in seconds; and k is in cm/s. Convert to m/s by dividing k by 100. Falling-head calculations require h₁>h₂>0.

Worked example (hypothetical values)

Constant-head example: specimen diameter 10 cm, length 20 cm, head difference 10 cm, outflow 100 cm³, and time 100 s give A=25π cm² and k=0.08/π≈2.546×10⁻² cm/s. Falling-head example: specimen diameter 10 cm, standpipe diameter 2 cm, length 20 cm, head falling from 80 to 20 cm over 600 s gives k≈1.848×10⁻³ cm/s.

Applicability and limitations

Laboratory one-dimensional permeability tests on saturated cylindrical soil specimens of constant cross-sectional area. Excludes field borehole, well, and pumping tests; unsaturated or non-Darcy flow; temperature or viscosity corrections; apparatus-loss corrections; and assessment of compliance with JIS, JGS, or ASTM test procedures.

Methods used

  • Constant-head test (FHWA-NHI-16-072 (2016), §10.2.3, Equation (10.3)): scope Saturated cylindrical specimen with a recorded constant total-head difference and steady outflow; region Global
  • Falling-head test (FHWA-NHI-16-072 (2016), §10.2.3, Equation (10.4)): scope Saturated cylindrical specimen with declining head in a standpipe of known cross-sectional area; region Global

Method and sources

Method: FHWA-NHI-16-072 (November 2016), §10.2.3, Equations (10.3) and (10.4). Data recorded: 2026-11-13.