Wood Equilibrium Moisture and Movement
Estimate wood equilibrium moisture content and radial/tangential movement from moisture changes or air temperature and humidity.
Results
—mm
—%
- Target moisture content
- —%
- Estimated final dimension
- —mm
- Change relative to initial dimension
- —%
- Selected total shrinkage (green → oven-dry)
- —%
Results update automatically when the required values are entered.
Method, applicability and sources
Calculation method
Equilibrium moisture content (%) follows USDA FPL-GTR-113 Equation (3-3): M=(1800/W)×[Kh/(1−Kh)+(K1Kh+2K1K2(Kh)²)/(1+K1Kh+K1K2(Kh)²)]. h=relative humidity÷100; T=air temperature (°C); W=349+1.29T+0.0135T²; K=0.805+0.000736T−0.00000273T²; K1=6.27−0.00938T−0.000303T²; K2=1.91+0.0407T−0.000293T². Dimensional change follows FPL-GTR-282 Equation (4-9): S(M)=S0×(1−min(M,30)/30); dimensional factor F(M)=1−S(M)/100; L2=L1×F(M2)/F(M1); ΔL=L2−L1. S0 is oven-dry shrinkage as a percentage of green dimensions. This approximation assumes a 30% fiber saturation point.
Worked example (hypothetical values)
For tangential white oak, a 200 mm width at 12% moisture changing to 6% uses S0=10.5%, F(12)=0.937, and F(6)=0.916. Estimated width is 200×0.916÷0.937=195.518 mm, a change of −4.482 mm.
Applicability and limitations
Wood from the 6 species listed in USDA Forest Products Laboratory Table 4-3, measured radially or tangentially. Equilibrium moisture is a practical approximation for wood in general. Excludes end-grain/longitudinal behavior, mixed grain, warping, internal moisture gradients, sorption history, treated wood, plywood, unlisted Japanese species, thermal expansion, short-term response, and guarantees of agreement with measured movement.
Methods used
- Equilibrium moisture content (FPL-GTR-113 (1999), Equation (3-3)): scope Approximation for 0–60 °C and 5–95% relative humidity; region Global
- Wood dimensional change (FPL-GTR-282 (2021), Equation (4-9) and Table 4-3): scope 6 listed species, radial/tangential directions, with an assumed 30% fiber saturation point; region Global
Method and sources
Method: FPL-GTR-113 (1999) §3 eq.(3-3); FPL-GTR-282 (2021) §4 eq.(4-9), Table 4-3. Data recorded: 2026-11-14.