Search Tools

Calculate the Wobbe index from volumetric heating value and relative density, and compare two gases

Indices are compared at the same reference conditions and heating-value basis. Similar values do not establish equipment interchangeability or safety.

What to calculate

When comparing two gases, use the same heating-value basis for both.

Confirm that volumetric heating value and relative density correspond to the same conditions. No conversion between conditions is performed.

Use the selected HHV or LHV basis and reference conditions. Zero represents a noncombustible gas.

Gas density / dry-air density at the same temperature and pressure. Dimensionless and greater than 0.

Results

Results update automatically when the required values are entered.

Method, applicability and sources

Calculation method

Wobbe index W = H / √d. H is volumetric heating value (MJ/m³) on the selected higher (HHV) or lower (LHV) basis; d is dimensionless relative density to dry air at the same reference conditions. kWh/m³ is converted using 1 kWh = 3.6 MJ. Difference ΔW = W(B) − W(A); relative difference = ΔW / W(A) × 100%. Relative difference is undefined when W(A) = 0. No conversion between reference conditions or estimation from composition is performed.

Worked example (hypothetical values)

HHV 38.62077 MJ/m³ and relative density 0.5971935 at 15 °C and 101.325 kPa give a Wobbe index of approximately 49.97622 MJ/m³.

Applicability and limitations

Gases with known heating value and relative density to dry air, measured or calculated at the same reference conditions for volume. Does not convert between reference conditions, estimate heating value or real-gas density from composition, calculate combustion air, or determine fuel compatibility, standards compliance or safety. Comparison does not certify equipment interchangeability.

Method and sources

Method: NBSIR 86-3057(1986)Definitions p.xiii / ISO 6976:2016 §3.5–3.6. Data recorded: 2026-11-14.