Steady Gaussian Plume Concentration Profile
Calculate receptor concentration and a crosswind profile at a fixed downwind position using known dispersion widths.
Enter all values in SI units. This calculator does not estimate σy and σz from coefficient tables. Numerical limits are computational constraints, not guarantees of model applicability.
Results
—g/m³
Results update automatically when the required values are entered.
Method, applicability and sources
Calculation method
Use independently supplied dispersion widths σy and σz at x>0. With perfect ground reflection: C=Q/(2πuσyσz)×exp[−y²/(2σy²)]×{exp[−(z−H)²/(2σz²)]+exp[−(z+H)²/(2σz²)]}. Without reflection, omit the second term in braces (the image-source term). Q[g/s], u[m/s], and x,y,z,H,σ[m] give C[g/m³]. The profile displays 7 points from y=−3σy to 3σy at the receptor's x and z.
Worked example (hypothetical values)
With perfect ground reflection, Q=1 g/s, u=1 m/s, H=y=z=0 m, σy=σz=1 m, and x=100 m, C=1/π≈0.31830989 g/m³. Here x identifies the location for the specified σ values and does not appear directly in the equation.
Applicability and limitations
Flat terrain, uniform steady wind, continuous point-source emission, downwind x>0, and independently known positive dispersion widths corresponding to that x. Excludes calm conditions, changing wind direction, complex terrain, building downwash, buoyant plume-rise estimation, mixing-layer reflection, chemical reactions, deposition, time variation, calibration to observations, regulatory review, and equivalence to EPA models.
Methods used
- Perfect ground reflection (image method) (Gaussian constant-wind / σ-direct v1.0): scope σy and σz specified at one downwind position x; region Global
- No ground reflection (Gaussian free-space direct term v1.0): scope Comparison equation omitting the ground image-source term; region Global
Method and sources
Method: E1235 Gaussian plume / σ-direct / ground-image optional v1.0 (2026-11-14). Data recorded: 2026-11-14.