Wastewater BOD/COD Load and Removal Efficiency

Report an issue

Calculate BOD or COD mass loads for industrial/commercial wastewater and compare influent and effluent loads using the same parameter.

Enter the same water-quality parameter and corresponding flow rates. This calculator does not assess discharge-standard compliance.

What to calculate

Enter together with the end date only if a period total is needed.

Both the start and end dates are included in the day count.

Results

Results update automatically when the required values are entered.

Method, applicability and sources

Calculation method

Daily load L(kg/day)=daily wastewater flow Q(m³/day)×BOD or COD concentration C(mg/L)÷1,000. Load reduction=influent L−effluent L. Removal efficiency (%)=load reduction÷influent L×100, only when influent L>0. If inlet and outlet flows differ, calculate each load with its own Q. Period total=daily load×(end date−start date+1 day). Daily flow and concentration are assumed constant throughout the period.

Worked example (hypothetical values)

A wastewater flow of 200 m³/day with a BOD concentration of 150 mg/L gives a load of 30 kg/day. If influent is 200 m³/day×150 mg/L=30 kg/day and effluent is 180 m³/day×20 mg/L=3.6 kg/day, load reduction is 26.4 kg/day and removal efficiency 88%. Over 3 days, influent load is 90 kg and effluent load 10.8 kg.

Applicability and limitations

Wastewater with measured concentrations of the same BOD/COD parameter and corresponding daily flows, treated as constant over the specified period. Excludes compliance with statutory effluent or total-load limits, assessment of sampling/measurement methods, automatic filling of missing measurements, varying daily-load integration, BOD–COD conversion, attribution of transfer to sludge or other fractions, and treatment-process optimization.

Method and sources

Method: E156 mass-load and load-based removal v1.0 (2026-11-13). Data recorded: 2026-11-13.