Multicomponent Vapor–Liquid Flash Calculation
Check phase splits and material balances using known vapor–liquid equilibrium ratios for a specified temperature and pressure.
Calculations keep the entered K values fixed. A meaningful equilibrium calculation requires K values valid at the specified temperature and pressure.
Results
—%
- Liquid fraction L/F
- —%
- Phase classification
- —
- Iterations
- —iterations
- Rachford–Rice residual |F(β)|
- —
- Maximum component material-balance residual
- —
Results update automatically when the required values are entered.
Method, applicability and sources
Calculation method
zᵢ=(1−β)xᵢ+βyᵢ; Kᵢ=yᵢ/xᵢ; F(β)=Σ[zᵢ(Kᵢ−1)/(1+β(Kᵢ−1))]=0; xᵢ=zᵢ/(1−β+βKᵢ); yᵢ=Kᵢxᵢ. β=V/F∈[0,1]. F(0) and F(1) determine the phase state; the two-phase case is solved by bisection.
Worked example (hypothetical values)
Synthetic binary example for checking the calculation: z=(0.6, 0.4), K=(0.25, 4) gives β=1/3, liquid x=(0.8, 0.2), and vapor y=(0.2, 0.8). These are not K values for actual substances.
Applicability and limitations
Nonreactive mixtures of 2–32 components with positive K values independently obtained at the specified temperature and pressure. Does not estimate K from temperature and pressure. Excludes property models, activity coefficients, equations of state, reactions, liquid–liquid or 3-or-more-phase systems, energy balances, and flow-unit conversions. For single-phase results, the absent phase's composition is not calculated.
Method and sources
Method: RR-supplied-K-2026-11-13-v1. Data recorded: 2026-11-13.