Search Tools

Japan: Building Coverage, Floor Area Ratio and Setbacks

Report an issue

Calculate reference building-footprint and FAR-counted floor-area allowances from verified site conditions and designated ratios, and compare the effect of road setbacks

Arithmetic results based on verified road classification, boundaries, regulatory values and road width. Road setback areas are excluded from the site, and the floor-area allowance covers only area counted toward FAR. The results do not establish buildability or the actual total floor area.

What to calculate

Enter the area including the road setback and the exclusions listed below. Do not subtract an area again if it has already been excluded.

Area established from road-boundary verification documents or equivalent records. Enter 0 if no setback is required or if it is already excluded from the site area above.

Area excluded from the site-area calculation that does not overlap the road setback. Enter 0 if none.

Enter the verified designated ratio. Corner-lot, fire-zone and other relaxations are not applied automatically.

Enter the verified designated ratio. Special additions and relaxations are not applied automatically.

The existing physical width may differ from the width used under Article 52. Use a value established after confirming road designation and boundaries.

Confirm zoning and the specified administrative authority's designation before selecting. Do not apply 0.8 to other areas.

Results

Results update automatically when the required values are entered.

Method, applicability and sources

Calculation method

A0 = site area before setbacks and exclusions; S = verified road setback area; E = other excluded area (m²). Calculated site area after setback A = A0 − S − E. Let C be building coverage ratio, F the designated floor area ratio (%), W the road width used under Article 52 (m), and k the verified coefficient. If W < 12 m, road-based FAR R = 100 × W × k (%), and applied FAR G = min(F, R). At 12 m or wider, G = F, with no reduction based on road width. Building-footprint allowance = A × C/100; FAR-counted floor-area allowance = A × G/100. The hypothetical no-setback comparison uses A0 − E under the same ratios and road conditions; setback differences are S × C/100 and S × G/100, respectively. Intermediate calculations are not rounded; displayed values use up to 3 decimal places. Differences are calculated from underlying values rather than by subtracting rounded displays.

Worked example (hypothetical values)

Example: site area before setback 200 m², road setback 10 m², other exclusions 0 m², building coverage ratio 60%, designated FAR 200%, fronting road width 4 m and coefficient 0.4. Applied FAR is 160%, calculated site area 190 m², building-footprint allowance 114 m² and floor-area allowance 304 m². Hypothetical no-setback allowances are 120 m² and 320 m², with differences of 6 m² and 16 m².

Applicability and limitations

Estimates for sites in Japan with one verified set of designated ratios and road conditions, and known excluded areas without double counting. Does not determine road classification, centerline, required setback width, boundaries, effective road width, zoning or eligibility for relaxations. Does not assess sites spanning different regulations, multiple fronting roads, statutory exceptions, floor areas excluded from FAR, slant-plane limits, height, shadow, road-frontage or fire-safety requirements. It is not a determination of buildability or building confirmation.

Method and sources

Method: General principles of Japan's Building Standards Act, Articles 42(2), 52 and 53 / Shizuoka Prefecture material updated 2023-01-11 and Yokohama City material updated 2024-08-13. Data recorded: 2026-11-13.