Bolt tightening torque and preload
Convert specified initial preload and effective tightening torque using a known K, and assess sensitivity to changes in the coefficient
Simple conversion based on the entered K and effective tightening torque. Bolt strength and safe tightening conditions are not assessed.
Results
—
- Result with K 10% lower
- —
- Result with K 10% higher
- —
- Lower K used in comparison
- —
- Higher K used in comparison
- —
Results update automatically when the required values are entered.
Method, applicability and sources
Calculation method
T [N·m] = K × d [mm] × F [kN]. Conversely, F [kN] = T [N·m] / (K × d [mm]). Values at 0.9K and 1.1K are also compared.
Worked example (hypothetical values)
Example: d = 10 mm, K = 0.2 and F = 10 kN give T = 0.2 × 10 × 10 = 20 N·m. Assuming K = 0.18 or 0.22 gives 18 or 22 N·m.
Applicability and limitations
Threaded joints with K verified by measurement or other evidence appropriate to the bolt, nut and bearing surfaces. Excludes automatic estimation of K; selection of suitable tightening values or allowable loads; strength, plasticity, thread failure, loosening, joint stiffness, temperature, relaxation over time, prevailing-torque corrections and statistical preload variability.
Methods used
- Torque–preload conversion using nut factor K (NASA-STD-5020B (2021), Eq. 24): scope Effective torque and initial preload using a known K; region global
Method and sources
Method: NASA-STD-5020B(2021-08-06)Appendix A.2, Eq. (24). Data recorded: 2026-11-13.