Search Tools

Convert specified initial preload and effective tightening torque using a known K, and assess sensitivity to changes in the coefficient

Simple conversion based on the entered K and effective tightening torque. Bolt strength and safe tightening conditions are not assessed.

What to calculate

The nominal bolt diameter, not the thread root or bearing-surface diameter.

Enter a verified value appropriate to the material, surface condition, lubrication and tightening method. An unverified K is not assigned automatically.

The initial axial force intended from tightening.

Results

Results update automatically when the required values are entered.

Method, applicability and sources

Calculation method

T [N·m] = K × d [mm] × F [kN]. Conversely, F [kN] = T [N·m] / (K × d [mm]). Values at 0.9K and 1.1K are also compared.

Worked example (hypothetical values)

Example: d = 10 mm, K = 0.2 and F = 10 kN give T = 0.2 × 10 × 10 = 20 N·m. Assuming K = 0.18 or 0.22 gives 18 or 22 N·m.

Applicability and limitations

Threaded joints with K verified by measurement or other evidence appropriate to the bolt, nut and bearing surfaces. Excludes automatic estimation of K; selection of suitable tightening values or allowable loads; strength, plasticity, thread failure, loosening, joint stiffness, temperature, relaxation over time, prevailing-torque corrections and statistical preload variability.

Methods used

  • Torque–preload conversion using nut factor K (NASA-STD-5020B (2021), Eq. 24): scope Effective torque and initial preload using a known K; region global

Method and sources

Method: NASA-STD-5020B(2021-08-06)Appendix A.2, Eq. (24). Data recorded: 2026-11-13.