Coil Inductance and Turn Count
Find reference values for self-inductance and target turn count from verified coil dimensions and magnetic-material conditions, or a core A_L value
Results
—
- A_L used in the calculation = L/N²
- —nH/turn²
- Turn count and achieved-value details
- —
- Model used
- —
Results update automatically when the required values are entered.
Method, applicability and sources
Calculation method
Cylindrical solenoid: L = µ0 µr N² π(d/2)² / ℓ. Rectangular-cross-section toroid: L = µ0 µr N² h ln(D_outer/D_inner) / (2π). Core A_L: L = A_L N². Dimensions are converted from mm to m, using µ0 ≈ 4π×10⁻⁷ H/m. The inverse calculation uses the positive root N* = √(L_target/A_L); the displayed count is the smallest integer that meets or exceeds the target, with a maximum of 1,000,000 turns. A_L is converted to H/turn² for calculation.
Worked example (hypothetical values)
For an air-core cylindrical solenoid with diameter 40 mm, length 100 mm, 200 turns, and µr=1, the result is approximately 631.655 µH (the OpenStax example gives 0.632 mH). With A_L=250 nH/turn² and a target of 100 µH, 20 turns are required and the achieved value is 100 µH.
Applicability and limitations
An estimate where the magnetic circuit can be idealized, or a winding design for which a corresponding A_L value is available in product documentation. Excludes end-effect corrections for short coils, spatially nonuniform cores, partially inserted cores, effective permeability calculations for gapped cores, magnetic saturation, DC bias, leakage flux, parasitic capacitance, frequency and temperature dependence, winding feasibility, and differences from measurements.
Methods used
- Long solenoid (OpenStax University Physics 2, §14.2, Eq. 14.13): scope Long, closely wound coil with a circular cross section, no end effects, and uniform linear permeability; region Global
- Rectangular-cross-section toroid (OpenStax University Physics 2, §14.2, Eq. 14.17): scope Rectangular cross section, uniform winding and medium, and no gap; region Global
- A_L value (TDK Electronics General Definitions, 2022-10, §3.2, p.8): scope Inductance factor matching the core and excitation conditions verified by the user; region Global
Method and sources
Method: E645-ideal-solenoid/toroid/AL-v1(2026-11-14). Data recorded: 2026-11-14.