Euler column buckling and effective length
Calculate elastic buckling load for a slender, uniform column under concentric axial compression with ideal supports
Theoretical value for a slender, uniform, linearly elastic column under concentric axial compression. This is not design resistance.
Results
—kN
- Effective length KL
- —m
- Effective length factor K
- —
Results update automatically when the required values are entered.
Method, applicability and sources
Calculation method
Theoretical buckling load Pcr = π²EI/(KL)². Effective length is KL (m). With E in GPa, I in cm⁴ and L in m: Pcr (kN) = 0.01 × π² × E (GPa) × I (cm⁴) / [K × L (m)]². Support factors K are ideal values.
Worked example (hypothetical values)
Example: E = 200 GPa, I = 800 cm⁴, L = 3 m and pinned–pinned supports (K = 1) give an effective length of 3 m and a theoretical buckling load of approximately 1,754.6 kN.
Applicability and limitations
Slender, uniform compression members with known Young's modulus, second moment of area about the flexural buckling axis and unbraced length. Excludes yielding, inelastic buckling, initial curvature, eccentric or lateral loading, shear deformation, torsional buckling, intermediate bracing, soil restraint, design resistance assessment and inverse calculations.
Methods used
- Euler elastic buckling with a uniform section and ideal supports (2026-11-13 v1.0): scope Slender columns under concentric axial compression, linear elasticity, a known buckling axis and ideal supports; region global
Method and sources
Method: Euler Pcr = π²EI/(KL)²; ideal K factors 0.5/0.7/1/2; v1.0. Data recorded: 2026-11-13.