Search Tools

Manning Equation and Normal Depth Calculator

Report an issue

Estimate discharge, mean velocity, and normal depth for uniform open-channel flow with a free surface.

Bottom width and side slope cannot both be 0. Assumes steady uniform flow, equal side slopes, and constant roughness.

What to calculate

A bottom width of 0 with a positive side slope gives a triangular section.

Horizontal distance divided by vertical height on one side. A value of 0 gives vertical walls, forming a rectangular section.

Enter the known roughness coefficient for the section.

0.001 means 1/1000. For steady uniform flow, this is assumed equal to the channel bed slope.

Results

Results update automatically when the required values are entered.

Method, applicability and sources

Calculation method

Flow area A=y(b+zy), wetted perimeter P=b+2y√(1+z²), hydraulic radius R=A/P, and top width T=b+2zy. Manning's equation in SI units is V=(1/n)R^(2/3)√S, Q=AV. The inverse calculation uses bisection to find y such that Q(y) matches the specified discharge (relative discharge error ≤10⁻¹⁰, up to 220 iterations, maximum search depth 1,000,000 m). Only displayed values are rounded; internal calculations are not.

Worked example (hypothetical values)

For a rectangular channel with bottom width 3 m, side slope 0, depth 1 m, n=0.015, and S=0.001: A=3 m², P=5 m, R=0.6 m, discharge is approximately 4.50 m³/s, and mean velocity is approximately 1.50 m/s.

Applicability and limitations

Preliminary assessment of open channels with a free surface and known geometry, roughness, and energy slope. Excludes full-pipe pressure flow, backwater and nonuniform flow, overtopping, changing geometry, compound sections or divided roughness, local losses, scour, sediment transport, and structure effects. Roughness and slope are not estimated automatically.

Methods used

  • Manning discharge calculation and normal-depth solution for uniform flow (HEC-RAS 6.6 (Uniform Flow Computations) and HEC-HMS Technical Reference Manual (SCS Unit Hydrograph Model)): scope Uniform roughness and flow slope; regular rectangular, trapezoidal, or triangular sections; SI units; region Global

Method and sources

Method: USACE HEC-RAS Hydraulic Reference Manual 6.6: Uniform Flow Computations / HEC-HMS Technical Reference Manual: SCS Unit Hydrograph Model (SI coefficient 1.00). Data recorded: 2026-11-13.