Ellipsoid Volume from Imaging Measurements
Calculate geometric or estimated volume from three measured mutually perpendicular diameters using the selected method
Enter three mutually perpendicular full diameters, not radii, in one unit. The general ellipsoid is a geometric model; organ-specific methods estimate volume from ultrasound.
Results
—mL
- Same volume in cubic centimeters
- —cm³
- Product of three diameters (after conversion to cm)
- —cm³
- Coefficient used
- —
- Method and structure
- —
Results update automatically when the required values are entered.
Method, applicability and sources
Calculation method
For full diameters L, W and H in cm, general ellipsoid V (cm³) = 4π/3 × (L/2) × (W/2) × (H/2) = πLWH/6. Prostate (AIUM 2025 Revision): V = 0.52 × LWH. Thyroid lobe (Konca / Elhan 2023): V = 0.524 × ML × AP × CC. For mm input, divide the product LWH in mm³ by 1000 once to convert to cm³. 1 cm³ = 1 mL. Results are rounded to two decimal places; intermediate values are not rounded. Changing the method or unit clears all three diameters to avoid carrying measurements over to a different structure.
Worked example (hypothetical values)
Example: length 5 cm, width 4 cm and depth 3 cm give a product of 60 cm³. General ellipsoid: π/6 × 60 = 10π ≈ 31.42 mL; prostate: 0.52 × 60 = 31.2 mL; thyroid lobe: 0.524 × 60 = 31.44 mL. Entering 50, 40 and 30 mm gives the same volumes because 60,000 mm³ / 1000 = 60 cm³.
Applicability and limitations
Clinicians with three measured mutually perpendicular full diameters of the same structure, all in the same unit. Do not mix radii, diameters from different structures, or nonperpendicular measurements. The thyroid method is for one lobe, not the whole gland. It does not assess lesions, malignancy, residual urine, normal ranges or surgical indications. Geometric and ultrasound estimates may differ from directly measured organ volume.
Methods used
- General ellipsoid (Exact geometric formula V = πLWH/6): scope An ideal ellipsoid with three perpendicular full diameters; region global
- Ultrasound estimate of prostate volume (AIUM Practice Parameter 2025 Revision(JUM 2026)): scope Three perpendicular prostate diameters measured by ultrasound; region global
- Ultrasound estimate of one thyroid lobe's volume (Konca & Elhan 2023、§2 Materials and Methods): scope Maximum ML, AP and CC diameters measured for one thyroid lobe; region global
Method and sources
Method: Wolfram MathWorld Ellipsoid equation (36) / AIUM 2025 Revision / Konca & Elhan, J Clin Med 2023, §2. Data recorded: 2026-11-12.