PCB Trace Current and Temperature Rise

Report an issue

Estimate current, required width, temperature rise, and copper resistance from finished trace cross-section and layer type using an empirical correlation.

Preliminary design estimates from the IPC-2221A empirical equation. Do not use them to determine overall PCB thermal design or safety.

What to calculate

The layer selection determines the IPC-2221A empirical coefficient.

Enter actual finished conductor thickness including plating, not nominal foil weight in oz (1–500 µm).

Used to calculate copper resistance at 20 ℃ (0.1–10,000 mm).

Enter the effective width of a uniform cross-section (0.01–100 mm).

Temperature rise above ambient (0.001–100 ℃), not absolute temperature.

Results

Results update automatically when the required values are entered.

Method, applicability and sources

Calculation method

Cross-sectional area A(mm²)=width(mm)×finished copper thickness(µm)/1000. A(mil²)=A(mm²)/0.00064516. IPC-2221A correlation: I(A)=k×ΔT(℃)^0.44×A(mil²)^0.725, with external k=0.048 and internal k=0.024. Inverse: A(mil²)=[I/(k×ΔT^0.44)]^(1/0.725), ΔT=[I/(k×A^0.725)]^(1/0.44). Width is rounded up to 1 µm. R20(Ω)=0.017241(Ω·mm²/m)×length(m)/area(mm²). Voltage drop=IR; loss=I²R. Results are displayed for current ≤40 A, temperature rise ≤100 ℃, width 0.01–100 mm, and copper thickness 1–500 µm.

Worked example (hypothetical values)

For an external trace 0.4826 mm (19 mil) wide and 71.12 µm (2.8 mil) thick with a temperature rise of 33.2 ℃, current is approximately 4.0 A. For length 10.16 mm (400 mil), resistance at 20 ℃ is approximately 5.10 mΩ.

Applicability and limitations

Approximate calculations for a single rectangular copper trace on a PCB with known finished thickness and width. Excludes guaranteed continuous current ratings, measured temperature distributions, copper planes or parallel traces, vias, pads, neck-downs, contacts, plating variations, heat paths, ambient temperature, stackup, copper-quality differences, high-frequency skin effect, fault safety, and IPC-2152 corrections.

Methods used

  • IPC-2221A empirical correlations for external and internal layers (IPC-2221A 2003 / TI TIDUCS7 2017): scope Uniform rectangular copper traces and approximate steady temperature rise. Does not apply IPC-2152 thermal corrections.; region Global

Method and sources

Method: IPC-2221A (2003) §6.2 empirical correlation; NBS Handbook 100 (1966), 100% IACS copper. Data recorded: 2026-11-14.