MOSFET Conduction and Switching Losses
Estimate selected losses and steady-state junction temperature for one MOSFET from entered electrical and thermal conditions.
Selected losses for one MOSFET. Gate-supply power is not uniformly added to heat generated in the die.
Conduction-only mode does not use switching or gate inputs. Temperature/RDS(on) interaction, Eoss, Qrr, and related effects are excluded.
Results
—W
- Estimated steady-state junction temperature
- —℃
- Conduction loss
- —W
- Switching overlap loss
- —W
- Gate-supply power (separate from die loss)
- —W
- Partial sum of die loss and gate-supply power
- —W
Results update automatically when the required values are entered.
Method, applicability and sources
Calculation method
Conduction loss Pcond = I_RMS² × R_DS(on). Full-cycle RMS already includes duty cycle, so it is not applied again. Triangular switching loss Poverlap = 0.5 × V_DS × I_switch × (t_rise + t_fall) × f_switch. Gate-supply power Pgate = Q_gate × V_gate × f_switch. Convert ns to s, kHz to Hz, and nC to C. Partial die loss Pchip = Pcond + Poverlap. Steady-state junction temperature Tj = T_ambient + Pchip × RθJA. Pgate is dissipated along the gate-drive path and is not included in Pchip for the thermal-resistance calculation.
Worked example (hypothetical values)
A full-cycle RMS current of 2 A and on-resistance of 0.1 Ω give 0.4 W conduction loss. Switching at 10 V, 2 A, 10 ns each for turn-on and turn-off, and 100 kHz gives 0.02 W overlap loss. Gate charge of 10 nC driven at 5 V requires 0.005 W gate-supply power. At ambient 25 °C and RθJA = 10 °C/W, partial die loss is 0.42 W and estimated steady-state junction temperature is 29.2 °C.
Applicability and limitations
One MOSFET with known full-cycle RMS current, selected operating conditions, RDS(on) at the relevant conditions, and mounting-system RθJA. Excludes Eoss/Qoss, Qrr, dead time/body-diode losses, CSI, parasitics, driver-circuit losses, temperature-dependent RDS(on), thermal transients, parallel devices, absolute-maximum or safety assessment, and circuit L/C design.
Method and sources
Method: E1042 v1.0 (constant R_DS; enter t in ns, f in kHz, and Qg in nC). Data recorded: 2026-11-14.