Approximate the relationship between measured resin cure depth and exposure to compare exposure conditions.

An approximation for the measured resin, wavelength, and exposure conditions. Do not reuse coefficients for a different light source or wavelength.

What to calculate
Measured exposure and cure depthRequired
RowExposure E₀ (mJ/cm²)Cure depth Cd (µm)Actions
1
2

Paste 2 tab-separated columns into the leftmost field. Up to 100 rows.

Record positive cure depths for the same resin, wavelength, and measurement method. Row order and duplicate points are retained. Blank or partially completed rows are not calculated.

Irradiance reaching the resin surface. 1 mW/cm² × 1 second = 1 mJ/cm².

Optional. At 0 seconds, cure depth is treated as 0 µm.

Optional. Enter a positive target depth. The time corresponding to 0 µm is not uniquely defined.

Results

Results update automatically when the required values are entered.

Method, applicability and sources

Calculation method

Jacobs equation: Cd=Dp×ln(E₀/Ec). For all-point regression, fit y=Dp×x+b by least squares with an intercept, where x=ln(E₀) and y=Cd, then Ec=exp(−b/Dp). Duplicate exposures each count as one point; points are not sorted and missing values are not imputed. The two-point method finds the same line from 2 measurements. Exposure E₀=irradiance I (mW/cm²)×time t (s). If E₀≤Ec, modeled cure depth is 0 µm; if E₀>Ec, Cd=Dp×ln(E₀/Ec). For positive target depth d, required exposure=Ec×exp(d/Dp), and required time=exposure÷I. R² is displayed only for all-point regression.

Worked example (hypothetical values)

Arithmetic verification example, not measured resin data: E₀=10,20,40 mJ/cm² and Cd=100ln(2),100ln(4),100ln(8) µm give Dp=100 µm and Ec=5 mJ/cm². With I=2 mW/cm² and t=10 seconds, E₀=20 mJ/cm² and estimated depth is approximately 138.63 µm.

Applicability and limitations

Paired exposure and positive cure-depth measurements using the same resin, wavelength, and measurement conditions. Do not include uncured measurements of 0 µm in the regression. Excludes mixed measurement conditions, nonlogarithmic or multiregion models, surface or post-curing, shrinkage, overexposure nonlinearity, and assessment of material safety or print quality.

Methods used

  • Jacobs working curve (Bennett 2017, Eq. (2)): scope Positive cure-depth measurements under the same material, wavelength, and test conditions; all-point regression or two-point calculation; region Global

Method and sources

Method: Bennett 2017 (Jacobs equation, Additive Manufacturing 18:203–212, equations (1)(2), sections 3.3–3.4). Data recorded: 2026-11-14.