Magnetic Circuit Air-Gap Flux and Force Calculator
Compare magnetic flux and reference attraction force for a single series magnetic path, accounting for core and air-gap reluctance.
Single-gap approximation that neglects leakage and fringing. Do not use the reference attraction force as a safe holding load.
Results
—T
—N
- Magnetic flux
- —mWb
- Core flux density
- —T
- Core field strength
- —A/m
- Air-gap field strength
- —A/m
- Core magnetomotive force drop
- —A·turn
- Air-gap magnetomotive force drop
- —A·turn
Results update automatically when the required values are entered.
Method, applicability and sources
Calculation method
Φ=BcAc=BgAg, NI=Hc(Bc)lc+(Bg/μ₀)g, F≈Bg²Ag/(2μ₀). B-H mode uses piecewise linear interpolation between measured points; constant-μr mode uses Hc=Bc/(μ₀μr).
Worked example (hypothetical values)
Illustrative calculation: core length 100 mm, cross-sectional area 1000 mm², gap 1 mm, pole area 1000 mm², 500 turns, 1 A and relative permeability 1000 give an air-gap flux density of approximately 0.571 T and reference attraction force of approximately 130 N.
Applicability and limitations
Approximation for a DC electromagnet with known mean core path length, cross-sectional areas and a single series air gap. Excludes leakage flux, fringing, multiple gaps or poles, permanent magnets, remanence, hysteresis, saturation prediction, AC losses, measured holding force, fall prevention, safety factors and coil inductance.
Methods used
- Piecewise linear magnetic path using a supplied B-H curve (2026-11-14-v1): scope Single air gap, initial magnetization branch, DC; region Global
- Linear magnetic path with constant relative permeability (2026-11-14-v1): scope Single air gap, DC, no saturation; region Global
Method and sources
Method: E646-ideal-series-magnetic-circuit-2026-11-14-v1. Data recorded: 2026-11-14.